消防报警和安全系统检测外文文献翻译@#@FireAlarmsandSecurityDetection@#@Afirealarmcircuit,asitsnameimplies,soundsanalarmintheeventofafire.Therecanbeoneorseveralalarmsthroughoutabuilding,andtherecanbeseveralalarmpoints,whichactivatethewarming.Thealarmpointscanbeoperatedmanuallyorautomatically;@#@inthelattercasetheymaybesensitivetoheat,smokeorionization.Thereareclearlymanycombinationspossible,andthischaptergivessomesystematicaccountofthewaytheyarebuiltup.@#@Severalalarmpointsareconnectedinparallel,andwheneveroneofthemisactuatedthecircuitiscompletedandthealarmsounds.Thisisdescribedasanopencircuit,anditwillbeseenthatitisnotfailsafe,becauseifthereisafailureofsupply,thefirealarmcannotwork.Anothercharacteristicofthiscircuitisthateveryalarmpointmustbecapableofcarryingthefullcurrenttakenbyallthebellsorhootersworkingtogether.@#@Thealarmpointsareconnectedinserieswitheachotherandwitharelaycoil.Therelayisnormallyclosedwhende-energized,andopenswhenthecoilisenergized.Thuswhenanalarmpointisactivatedtherelaycoilisde-energized,therelayclosesandthealarmsounds.Thissystemfailssafetotheextentthatifthecoilcircuitfailsthemaincircuitoperatesthealarm.Itisnotofcoursesafeagainsttotalfailureofthesupplybecauseinthateventthereisnosupplyavailabletoworkthebells.Thealarmpointsdonothavetocarrytheoperatingcurrentofthebellsorhooters.Thisarrangementiscalledaclosedcircuitincontrasttotheopencircuit.Wecannoticethatinanopencircuitthealarmpointsarewiredinparallelandarenormallyopen,whilstinaclosedcircuittheywiredinseriesandarenormallyclosed.@#@Atypicalmanuallyoperatedfirealarmpointiscontainedinarobustredplasticcasewithaglasscover.Thematerialischosenforitsfireresistingproperties.Thecasehasknockoutforconduitentriesattopandbottombutthematerialcanbesufficientlyeasilycutforthesiteelectriciantomakehimselfanentryinthebackifheneedsit.Alternativeterminalsareprovidedforcircuitsinwhichthecontactshavetoclosewhentheglassissmashedandforcircuitsinwhichthecontactshavetoopenwhentheglassissmashed.Intheformercase,thereisatestswitchwhichcanbereachedwhenthewholefrontisopenedwithanAllenKey.Inthelattercase,thetestpushisomittedbecausethecircuitisinanycaseofthefailsafetype.Thealarmpointillustratedissuitableforsurfacemounting.Similaronesareavailableforflushfixingandinweatherproofversions.Thecurrentcarryingcapacityofthecontactsshouldalwaysbecheckedwiththemaker'@#@scatalogue.@#@Athermallyoperatedalarmpointconsistsofabi-metalstripthatdeflectswhenthetemperaturerises,andtherebytiltsatubehalffullofmercury.Whenthetubetiltsthemercuryflowsintotheotherhalfofthetubewhereitcompletesthecircuitbetweentwocontactspreviouslyseparatedbyair.Alternatively,thearrangementwithinthetubecanbesuchthatthemercurybreaksthecircuitwhenthetubeistilted.Thecasingofthealarmisofstainlesssteel.Heatdetectorsofthistypeareusuallysettooperateat65℃.Theyarefrequentlyusedinboilerhouses.@#@Asmokeoperatedalarmpointwouldbeusedonlyinspecialcircumstanceswhichmakeitnecessarytodetectsmokeratherthanheat.Thistypecancausenuisanceoperationofthealarmbyreactingtosmallquantitiesofsmokewhichhavenotbeencausedbyafire;@#@theyhaveforexamplebeenknowntosoundthealarmasaresultofcigarettesmokeinanoffice.Modernoneshaveadjustablesensitivitysothattheycanbesettoavoidnuisanceoperation.@#@Anionizationdetectorcontainsachamberwhichhousessomelowstrengthradioactivematerialandapairofelectrodes.Theradioactivematerialmakestheairinthechamberconductivesothatasmallcurrentflowsbetweentheelectrodes.Thesizeofthecurrentvarieswiththenatureofthegasinthechamberandassoonasanycombustion.Productsareaddedtotheairthereisasuddenchangeinthecurrentflowing.Thedetectoralsohasasecondchamberwhichispermanentlysealedsothatthecurrentthroughitneverchanges.Aslongasthecurrentsthroughthetwochambersareequalthereisnooutput,assoonastheybecomeunbalancedthereisanetoutputwhichisusedtooperateatransistorswitchinthemaincircuitthroughthedetector.@#@Thehumanbeingisthemostefficientfiredetector,providedthatheisactuallythereatthetime.Thecombinationofhiseyes,earsandnoseallowshimtodifferentiatebetweenvariousphenomena.Hecansmellthedifferencebetweencigarettesmoke,burningtoastandsomethingmoresinistersuchasburningpaper.Hecanseesmokeandflamesandwilloftenhearafirebeforehehasnoticedeithertheflamesorthesmoke.Sometimes,thefirstthinghenoticesisheat,forexample,ahotpartitionwall.Itisthesephenomenathatfiredetectordesignersmeasuretodetecttheonsetoffire.Itistheonsetoffirethatiscrucial;@#@verysmallfirescanbeputoutquicklyandsafelywithportablefireextinguishers,orevenacupofcoffeeifdetectedsoonenough.Obviously,thesmallerthefire,thelessitmaybeobserved.Firedetectorsmust,therefore,bedesignedwithouttheriskoffalsealarms.Sowhattechnologyisusedtodaytodetectthesephenomena?
@#@@#@Twotechniquesareusedforthedetectionofsmoke:
@#@photoelectricsmokedetectorsandionizationsmokedetectors.Photoelectricdetectorsarearrangedsothat,althoughvisiblelightcannotenter,smokecanenterfreely.Thistypeofdetectorisbasedonamattblackchamberaboutthesizeofacoffeecup.Adividingwallisplacedinthemiddleofthechamberoneithersideofwhichislocatedalighttransmitterandalightreceiver.Undernormalcircumstances,lightfromthetransmitterisnotreceivedbythereceiver,asthechamberisnotreflective.Whensmokeparticlesenterthechamber,lightbouncesofftheseparticleswhichresultsinasignalbeingreceived.Asimilareffectcanbeobservedwhensunshineentersasmokyroom.Thesephoto-electricdetectorsarehighlysensitiveandreliable,solongasthesmokeparticlesarevisible.@#@Certainclassesoffire,however,emitinvisiblesmokeparticleslongbeforethefireisactuallyalightandinthesecasesanionizationsmokedetectormustbepresent.Althoughthedesignofthesedetectorsisslightlymorecomplicatedthaninthecaseofphoto-electricdetectors,thebasicprincipleisverysimple.Twometalplatesareseparatedbyseveralmillimetersandavoltageisappliedacrossthem.Sinceairdoesnotconductelectricity,nocurrentflows.Ifanionizingradioactivesourceisbroughtclosetotheplatesthentheairitselfisionized,thatis,electricallychargesparticlesarepresentbetweentheplatesandtheseallowatinycurrenttoflow.Anyparticlesenteringthechamber,eithervisibleorinvisible,tendtoneutralizetheions,thusdecreasingthecurrentflow.Itisthisreductionincurrentwhichismonitoredinmeasuringtheamountofsmokethatispresent.@#@Firedetectionanditscorrespondingsafetysystemsarecrucialpartsofanintelligentbuilding.Thispaperreviewsthecurrentstateofdevelopmentoffiredetectionandalarmsystemsintheintelligentbuilding.Newtechnologiesandconceptsdevelopedinintelligentbuildings,suchasadvancedmulti-functionsensors,computervisionsystemsandwirelesssensors,real-timecontrolviatheInternet,andintegratedbuildingservicesystems,havealsobeenreviewedanddiscussed.Thesenewtechnologiesandconceptswillimprovethecapabilityoffiredetectionsystemstodiscriminatebetweenfireandnon-firethreatsandwillincreasethetimeavailableforpropertyandlifeprotection.However,mucheffortisstillneededtoremovebarrierstothefurtherdevelopmentofthesenewtechnologies.@#@Newsensortechnologieswillbekeycomponentsinthenextgenerationofintelligentbuildings.Currentintelligentbuildingsoftenhaveembeddedprocessorsanddedicatedinformationnetworks.Thenewgenerationisexpectedtoaddthecapabilitytolearnaboutthebuildingscircumstancesanditsoccupantsneedsandchangethebehaviorofitscontrolsystemsaccordingly.Theemploymentofalargenumberofsensorswithinthebuildingwillallowittooperateinaresponsivemanner,ratherthanusingpre-programmedcontrolmodelsasareemployedinthefirsttwogenerationsofintelligentbuilding.Theinformationprovidedbysensorsincludeschangesinbothinternalandexternalenvironmentsofabuilding,suchassmoke,temperatureandhumidity,airquality,airmovement,andthenumberofbuildingoccupantsaswellasahostofotherproperties.Thesystemwillusesensorstoidentifyhowaparticularpersontendstoreacttoparticularcircumstancesandtolearndifferentbehaviorsfordifferentpeople.Thenumberofsensorsrequiredtoobtainthistypeoffunctionalityisquitehigh,especiallysinceoneofthemajorgoalsofintelligentbuildingsistoallowindividualizedcontrolofanenvironment.Thisneedwillincreasethecostofintelligentbuildingsandmakeitdifficulttomanagetheresultinglargeamountofdata.Developmentofcost-effectivesensorshasconsequentlybeenidentifiedasakeyneedforintelligentbuildings.Fortunately,manyofthepropertiesthatneedtobemonitoredcanbeusedformultiplepurposes.Securitysystemsthatcantracktheentryandexitofoccupantsfromanofficebuildingcanalsobeusedtoensurecompleteevacuationofabuildingduringafireoreven,inmoreadvancedforms,determinewhereoccupantsmaybetrappedandunabletoescape.Similarly,parameterssuchastempera
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 消防 报警 安全 系统 检测 外文 文献 翻译