冻干机操作手册范文Word格式.docx
- 文档编号:21774406
- 上传时间:2023-02-01
- 格式:DOCX
- 页数:181
- 大小:1.38MB
冻干机操作手册范文Word格式.docx
《冻干机操作手册范文Word格式.docx》由会员分享,可在线阅读,更多相关《冻干机操作手册范文Word格式.docx(181页珍藏版)》请在冰豆网上搜索。
safety,introduction,PCoperationdescription,lyophilizeroperationdescription,alarmandfailureanalysis,terminologyandabbreviations.
Forbetterintroductionoftheproductdetails,thediagramsinthemanualarethestatuswithoutthecovers.Whenoperatingtheproducts,pleasemakesurethecoversareinstalledandoperateaccordingtothemanualdescription.
Thediagramsinthismanualareonlyexamples,whichmayhavedifferencesfromyourpurchasedproducts.
Forimprovingtheconvenienceofthemanual,thecontentsinthemanualmaybetimelyupdatedwhentheproductsandspecificationupdates.
Ifyouneedtoordertheoperationmanualduetodamageandlosing,pleasecontactourcompanyortheofficesittingnearesttoyouinthebackcoverandtellusthereferencenumberinthecover.
Ifthewritingsonthenameplateinstalledintheproductsblurs,pleaseorderfromourcompanyortheofficesittingnearesttoyouinthebackcover.
本手册包含:
安全、简介、上位机操作说明、冻干机机操作说明、常见报警及故障分析、术语和缩写六个部分。
为了说明产品的细节部分,本说明书中的图解有时为卸下外罩或安全遮盖物的状态。
运行本产品时,请务必按规定装好外壳或遮挡物,并按使用说明书的内容进行运行。
本操作手册中的图示仅为代表例,可能会与您订购的产品有所不同。
由于产品改良或规格变更,以及为了提高操作手册的便利性,本操作手册的内容会及时变更。
由于损坏或遗失而需要订购操作手册时,请向本公司或者封底上记载的离您最近的本公司营业所联系,并告知封面上的资料编号。
安装在产品上的铭牌如果已经字迹模糊或发生破损时,请向本公司或封底上记载的离您最近的本公司营业所订购。
Tableofcontents
1SafetyRelatedMarks与安全有关的标记说明
Thismanualusesthefollowingmarksbasedonthesafetycontents.
本手册根据与安全有关的内容,使用了下列标记。
Thesafetyrelatedmarksareextremelyimportanttofollow.
有安全标记的说明,表示重要内容,请务必遵守。
Incorrectusagemaycauseinjuriesordeath.
表示错误使用时,将会引发危险情况,导致人身伤亡。
Incorrectusagemaycausemildormoderatepersonalinjury.Moreovertheequipmentwillbedamaged.
表示错误使用时,将会引起危险情况,导致轻度或中度人身伤害,损坏设备。
However,eventheattentionitemsmaycausemajoraccidentbasedontheactualsituation.
但是,即使是事项,根据具体情况,有时也可能导致重大事故。
Evenitemsdonotbelongto“danger”or“attention”,wealsomarkintherelevantplaces.
即使不属于“危险”或“注意”,但需要用户遵守的事项,也在相关的地方同时进行了标记。
1.1Safetynotice安全注意事项
1.1.1BeforePower-on上电前
Attention注意
Pleaseconfirmwhetherthevoltageoftheexternalmaincircuitpowersupplyisthesamewiththeratedvoltageofthecabinettransformer,otherwiseitwillresultininjuryandfire.
·
请确认外接交流主回路电源的电压与电控柜变压器额定电压是否一致;
否则会有引起人员受伤和火灾的危险。
Donotperformpressuretestwiththecabinetcomponents,otherwisethecomponentswillbedamaged.
请勿对电控柜各元件进行耐压试验;
否则会造成电器元件的损坏。
Thecontrolcircuits,testcircuitsandothercircuitshavebeenconnectedandtested,sonon-staffscannotchangethecircuits.Otherwiseitmaycausefireandthedamageofthefrequencytransformer,transformer,motor,andotherunits.
控制回路和检测回路等线路已接好并测试出厂,非工作人员切忌修改线路;
否则会有引发火灾的危险。
另外,还有可能造成变频器、变压器、电动机以及其他单元的损坏。
Pleasefastentheterminalscrewbasedonthespecifiedtorque;
otherwisethefirewillbecaused.
请按指定的力矩来紧固端子螺丝;
Pleasepaygreatattentiontothesafetyinstructionsonthecabinetandcleaningmachine;
otherwiseitwillresultininjuryandfire.
请重视电控柜及清洗机本体上的安全指示;
Pleasemakesurethesitetemperatureisbetween-15℃~45℃,andrelativehumiditybetween40%-70%RH.Oritwillresultincasualtiesandfire.
请确保现场环境在-15℃~45℃,相对湿度在40%-70%RH;
否则会有引发火灾及造成人员伤亡的危险。
Danger危险
Pleasemakesurealltestingcomponents(flowswitch,temperatureswitch,thermalresistor,gauge)areundamagedandreliablyconnected;
otherwisetheoperatingequipmentwillbeseriouslydamagedandresultinpersonalcasualties.
请确保所有检测元件(流量开关、温度开关、热电阻、压力表等)连接可靠、未损坏;
否则会引起运行中的设备严重损坏并造成人员伤亡。
Pleasemakesurethepowersupplyandthemotorswitchareoff;
otherwiseelectricshockandfirewillbecaused.
上电前,请确认输入电源和马达开关是否处于OFF状态;
否则会有引发触电和火灾的危险。
Thewiringoperationshallbeperformedbytheprofessionalelectrician;
otherwiseelectricshockandfirewillbecaused.
接线作业请由专业的电工人员进行;
Pleasemakesurethegroundingterminalsconnectreliably;
请务必确保接地端子接地可靠;
1.1.2MechanicalSafety机械安全
TheequipmentisdesignedandmanufacturedfollowingtheISO12100part1,part2andISO61508relatedmechanicalsafetystandards.ThespecificriskanalysisandsolutionspleaserefertoFSMechanicalSafety
本设备根据ISO12100第1及第2部分、ISO61508等相关的机械安全标准设计及制造的,具体风险分析及方案请参考FS中机械安全的描述。
1.1.3EmergencyStop紧急停止
Threeemergencystopbuttonsaremountedintheequipment.Oneisfittedonthecontrolpanelofthecabinetandtheotherinthecontrolboxbesidethemaindoorinthemachineroom.Therestoneissharedwiththeloading/unloadingsysteminstalledinthesterileroom.Onceanybuttonispressed,thehardwareinterlockoftherelevantsafetycircuit(safetyswitch+safetyrelay)willcutofftheallthecontrolpowerexcepttheinstrumentpower.Allthepowerequipmentswillstopandvalveswillbeinoriginalstatus(singleelectriccontrol)orcurrentstatus(doubleelectriccontrol).Alltheinstrumentspowerwillbesavedtomonitortheequipmentstatusandrelevantprocessparameters.Detailsareasfollows:
三个急停按钮安装在这台设备上,一个安装在控制柜的控制面板上,一个并联到机器房箱体主门旁边的控制盒,另外一个与手动进出料系统共用安装在无菌室内,任何一个被按下后,相应的安全回路(安全开关+安全继电器)的硬件连锁将切断除仪表电源外的所有控制电源,所有的动力设备将停止,阀门将处于原始状态(单电控)或当前状态(双电控)。
所有仪表电源将被保留以监视设备状态及相关的过程参数,具体如下:
Location
位置
Name
名称
Power
电压
Site
现场
equipmentinputstatus(e.g.opened/closed)
设备输入状态(如:
开关状态)
DC24V
vacuumandpressuretransmitter
真空和压力变送器
Electriccontrolcabinet
电器控制柜
Temperaturesensor
温度传感器
PLC(notincludePLCoutput)
PLC(不包括PLC输出)
AC230V
Recorder
记录仪
ControloutputfromPLCtoalarminghornandalarminglight(closeofthemainvalves)
PLC到报警喇叭、总报警灯等的控制输出。
(如:
主阀的关闭等)
EmergencyStopReset:
紧急停止复位:
Afterresettingtheemergencystopbutton,alarmingconfirmbuttonandresetbuttonshallbepressedatthesametime.Theemergencystopwillreset.
复位急停开关后,同时按下电控柜面板上“报警确认按钮”及“复位按钮”,紧急停止将复位。
Makesurethefreezedryerstopsbeforeresettingtheemergencystopandthefailurehavebeenremoved.Otherwisethecommandwillbeexecutedimmediatelyafterresetting,whichmaycausepersonalinjuryandequipmentdamage.
复位紧急停止前,请务必确保冻干机处于停止状态,且故障被排除,否则复位后,指令将立即进行,导致人员受伤或设备损坏的危险。
1.1.4MaintenanceandInspection维护与检查
Itisextremelydangerousthatthecabinethashigh-pressuredterminalsinside.Donotcontactoryouwillgetanelectricshock.
电控柜内有高压端子,非常危险。
请勿随意触摸,否则会有触电的危险。
Neverattempttoremovetheprotectioncoverwhenitispoweredon.Ifthecoverneedtoberemoved,docutoffthebreakerforwiringoryouwillgetanelectricshock.
在通电状况下,请务必不要拆卸保护罩。
如果需要拆卸保护罩时,请务必断开接线用的断路器。
否则会有触电的危险。
Docutoffthepowersupplyofthemainloop,confirmingthechargingindicatorisout,andthenmaintainandcheck.
请切断主回路的电源,确认充电指示灯熄灭后,再进行维护与检查作业。
Exceptthespecifiedpersonnel,othersdonotmaintain,checkandreplacethecomponents.
除指定的人员以外,其它人请勿进行维护、检查或更换部件。
Beforeoperation,pleasetakeoffthemetalaccessories(watch,ring)anduseinsulatedtools,oryouwillgetanelectricshock.
作业前,请摘下身上的金属饰物(手表、戒指等)。
作业时,请使用进行了绝缘处理的工具。
Whenusingthelifter,pleasetakeprotectionstoavoidlower.Otherwisethereareriskstogethurt.
使用升降机时,请在机器侧采取以防落下等的安全措施。
否则会有受伤的危险。
Neverattempttochangethewiringordismountjumperwhileitispoweredon,otherwiseitwillcauseinjury.
正在通电时,请勿变更接线或拆装跳线,否则会有导致受伤的危险
2LyophilizerIntroduction冻干机简介
2.1Purpose冻干机用途
Thelyophilizerisoneproductintegratesfreezingtechnology,dryingtechnologywithfluidtechnology.
冻干机是集冷冻技术、干燥技术、流体技术于一体的产品。
2.2Configuration冻干机配置
No.
序号
BaseMachine基本型
Configuration配置
1
Model设备型号
2
Language语言
English+Chinese英文+中文
3
SafetyConformanceCertification安全认证
NO无
4
MainPowerSupply主电源
3P/AC400V/50HZControlPower:
24VDC3P/AC400V/50HZ控制电源:
24VDC
5
CityPowerSupply单相电源
220-240V
6
SIP
Yes有
7
CIP
8
SlotDoor小门
9
AutoLoading/Unloadingsystem自动进出料系统
10
FlammableSolventProduct可燃溶剂产品
11
HighPotentProduct危险产品
12
Unit单位
Unit公制
Optionalconfigurationsareasfollows:
本项目的选项配置如下:
Options可选项
PressureVesselCodes压力容器标准
GB150
CoolingJacket冷却夹套
ChamberRibMaterial加强筋材料
Carbonsteel碳钢
HydraulicStoppering液压压塞
ShelfRamBellows板层波纹管
MainValveBellows主阀波纹管
BackPusherBellows后推波纹管
ShelfStack板层
10+1
VariableShelfSpacing可变板层间距
Fixed固定
SterileFilter无菌过滤器
1
FilterAutoTest过滤器自动检测
SanitaryValves卫生级阀门
13
VacuumPump真空泵
2
14
MechanicalBoosterPump机械增压泵
15
Compressor压缩机
MYCOM
16
ChamberExpansionValve箱冷膨胀阀
Electronic电子
17
CondenserExpansionValve阱冷膨胀阀
Thermal热力
18
Refrigerant制冷剂
R404A
19
PLCBrandPLC品牌
SIEMENS
20
Recorder记录仪
YOKOGAWA24通道
21
AbsolutePressureMeasurement绝对压力测量
22
MKS真空调节阀MKSVacuumModulatingValve
No无
23
ElectronicSignature电子签名
(CFR21Part11Compliance)(遵从联邦法规21章第11款)
24
ConfigurableBatchReport可选择报表
25
UPS不间断电源
6KVA
26
PLCRemoteAccessModem远程访问模块
27
IQ/OQ
28
GAMP
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 冻干机 操作手册 范文