400GB/10KSAS
450GB/15KSAS
500GBSATA
750GBSATA
1TBSATA
RAIDGroup
MaxRG
50
75
100
RAIDLevel
6/5/1+0/1(SAS&
SATA)0(SASonly)
LU
MaxLU#
2048
4096
MaxLUsize
60TB
FC
I/F
1/2/4Gbps
1/2/4Gbps
I/FPorts
(SFP)
Max2/CTL
4/system
Max4/CTL
8/system
Max8/CTL
16/system
iSCSI
1Gbps(1000Base-Tcopper)Ethernet
Heightbaseunit
4U
Heightexpansionunit
3U
DualController
Default
Cache(4GBDIMM)
Slot
1/CTL
2/CTL
4/CTL
Capacity
4GB/CTL
8GB/system
8GB/CTL
16GB/system
16GB/CTL
32GB/system
MaximumCache
2GBDIMMs
4GBperarray
8GBperarray
16GBperarray
4GB
DIMMs
32GBperarray
InternalBatteries
2
2(default)
2(optional)
InternalBatteryBackupTime
2GB/4GBDIMMs
24/48hours
24/30hours
ExternalBatteries
N.A.
1or2
ExternalBatteryBackupTime(withmaximuminternalbatteries)
One
90hours
Two
N.A
144hours
MaximumCacheperCTL
1
4
Additional#
n/a
1.2技术亮点
(1)在线升级,实现真正的active-active;
(2)高密扩展柜;
只支持1T的SATA盘,与普通盘不同
(3)SAS网络;
(4)支持所有多路径软件,将多路径安装部分交给主机工程师;
(5)SNM2页面管理软件。
第2章存储硬件安装
2.1磁盘阵列硬件安装配置
普通扩展柜:
高密扩展2100,2300:
高密扩展2500:
第3章存储软件安装配置
3.1整体说明
AMS2000系列的一个最大的技术特点就是支持所有的多路径管理软件,因此将此部分的操作交给主机工程师去做,我们只是正常的初始化安装,创建RAIDGROUP,创建虚端口HOSTGROUP,主机正常认到盘路径即可。
3.2存储配置安装
3.2.1SNM2安装
AMS2000系列的存储管理软件已经改为SNM2,原来1000系列用的SNM不能管理2000系列,但是SNM2可以管理1000系列,在用SNM2对存储进行高级管理时需要安装JAVA1.6.10版本(JAVA1.6.06也没问题)。
为了避免出现在SNM2里查看Settings→AdvancedSettings时出现内存不足的情况,需要将JavaRuntimeParameter值设置为-Xmx192m。
设置方法:
Start→Run→ControlPanel→Java→(JavaAppletRuntimeSettings)View-JavaRuntimeParameter→-Xmx192m。
SNM2采用的是Client-Server设计架构,如果客户有安装了SNM2的管理机,我们自己的PC机就不用再安装SNM2软件,直接在IE中输入http:
//<
IPaddressofhost>
:
23015/StorageNavigatorModular/
其中的IP并不是存储的IP。
而是管理机的IP,如果在自己的PC中也安装了SNM2,则自己的笔记本既可以是客户端,也可以是Server主机。
3.2.2初始化安装
1)登陆SNM2服务器,在IE中输入
http:
23015/StorageNavigatorModular/其中ip可能是专门服务器IP,也可能是你自己的IP.用户名为system密码manager
2)登陆存储设备
点击AddArray
点击Next
输入存储IP地址,设备初始IPUser口–192.168.0.16/17Maintenance口-10.0.0.16/17
添加存储成功
3)初始安装向导
点击InitialSetup
创建E-mailAlert,一般是disable
设置控制器管理口IP地址
设置前段端口,直连Topology为Loop,连交换机则是Point-to-Point
创建热备盘
设置系统时间,确认信息后Next,Finsh完成
4)创建RAIDGROUP
5)创建LU
6)创建虚端口HOSTGROUP
虚端口就是将前段端口的WWN号与主机HBA卡的WWN号进行绑定,可以理解为对应着EMC中的每个链路及时一个虚端口。
在创建虚端口的过程中可以通过选择H-LU和LU进行主机绑定,其中H-LU就是主机上认到盘的ID,如H-LU为000,则在主机上认到的设备就是d0。
至此就已经完成了存储端的配置,只要在主机端能正常的识别到划分的设备,则我们的任务就已经完成。
7)激活HostGroupSecurity
如果没有激活HostGroupSecurity,AMS的前端port只能属于一个HostGroup,这会导致只有一种操作系统平台可以连接该端口.。
如果想让该port属于不同的HostGroup,就需要激活port的HostGroupSecurity属性。
选中需要激活的port,点击右下角的ChangeHostGroupSecurity,按照提示就可以进行修改。
3.2.3收集Trace信息
Trace信息可以通过web界面或SNM2两种方式收集
3.2.3.1WEB方式收集Trace
3.2.3.2SNM2收集Trace
点击Alerts&
Events后,点击右上角的CollectTrace
点击Download
3.2.4安装License
1.选择安装向导
2.选择keycode
3.有些license在安装之后要重启存储,安装之前需确认
4.新阵列需要安装BOS-MLicenseKey激活阵列的基本功能。
安装完BOS-MLicenseKey后会出现很多管理功能不可见的情况,可以通过设置root用户权限来解决。
设置完成后,logout后重新login即可。
3.3系统微码升级
1.按设备后面的RST键,登陆web界面,进入工程师模式。
用户名:
maintenance,密码:
hosyu9500。
2.安装JAVA环境配置
TwoJavaconfigurationfilesmustbepresentinordertoperformthemicrocodereplacement:
C:
\ProgramFiles\Java\jre1.6.0_07\lib\ext\HTTPClient.jar
\DocumentsandSettings\Administrator\.Java.policy
3.关闭IE浏览器阻止弹出窗口阻止程序
如果不关闭IE浏览器的阻止弹出窗口程序,会导致升级微码窗口无法弹出。
4.安装,选择update则为升级微码,initialsetup为重灌微码
5.如果为InitialSetup,安装完成后需要设置设备序列号,否则系统报错。
首先按RST键,使系统进入维护模式。
在IE中输入.168.0.16/equip_set
在下面界面中设置系统序列号:
系统的序列号在机器后面右方机柜内侧,为000开头的8位数字,在设置系统SN时,需要根据机器型号将000替换为830、850或870,对应关系如下:
830XXXXX=AMS2100
850XXXXX=AMS2300
870XXXXX=AMS2500
第4章HDLM软件安装配置
4.1整体说明
4.2IBMAIX平台软件安装
4.3Solaris主机认盘及多路径配置实例
查看主机光纤卡的WWN
#fcinfohba-port
HBAPortWWN:
10000000c942c3dd
OSDeviceName:
/dev/cfg/c1
Manufacturer:
Emulex
Model:
LP9002L
FirmwareVersion:
3.92a2
FCode/BIOSVersion:
none
Type:
N-port
State:
online
SupportedSpeeds:
1Gb2Gb
CurrentSpeed:
2Gb
NodeWWN:
20000000c942c3dd
10000000c942c52e
/dev/cfg/c2
20000000c942c52e
扫盘
#cfgadm-al
Ap_IdTypeReceptacleOccupantCondition
c0scsi-busconnectedconfiguredunknown
c0:
dsk/c0t0d0diskconnectedconfiguredunknown
dsk/c0t2d0CD-ROMconnectedconfiguredunknown
c1fc-fabricconnectedconfiguredunknown
c1:
10000000c942bdd4unknownconnectedunconfiguredunknown
10000000c942c465unknownconnectedunconfiguredunknown
10000000c942c52eunknownconnectedunconfiguredunknown
50060e8005afe030diskconnectedconfiguredunknown
50060e8010452150diskconnectedconfiguredunknown
50060e8010452152diskconnectedconfiguredunknown
c2fc-fabricconnectedconfiguredunknown
c2:
10000000c942c3ddunknownconnectedunconfiguredunknown
50060e800427fd10diskconnectedconfiguredunknown
50060e800427fd30unavailableconnectedunconfiguredfailed
50060e8005afe030unavailableconnectedunconfiguredfailed
50060e8010452150unavailableconnectedunconfiguredfailed
50060e8010452152unavailableconnectedconfiguredfailed
#devfsadm
#format
Searchingfordisks...done
c1t50060E8010452152d0:
configuredwithcapacityof975.00MB
c1t50060E8010452150d0:
AVAILABLEDISKSELECTIONS:
0.c0t0d0<
ST380021Acyl38307alt2hd16sec255>
/pci@1e,600000/ide@d/dad@0,0
1.c1t50060E8005AFE030d0<
HITACHI-OPEN-V-CM-6004cyl10alt2hd15sec512>
/pci@1e,600000/fibre-channel@4/fp@0,0/ssd@w50060e8005afe030,0
2.c1t50060E8010452152d0<
HITACHI-DF600F-0000cyl52alt2hd50sec768>
/pci@1e,600000/fibre-channel@4/fp@0,0/ssd@w50060e8010452152,0
3.c1t50060E8010452150d0<
/pci@1e,600000/fibre-channel@4/fp@0,0/ssd@w50060e8010452150,0
4.c2t50060E800427FD10d0<
HITACHI-OPEN-V-CM-5009cyl10alt2hd15sec512>
/pci@1e,600000/fibre-channel@5/fp@0,0/ssd@w50060e800427fd10,0
5.c3t50060E8010452150d1<
HITACHI-DF600F-0000cyl166alt2hd50sec768>
/pseudo/dlmndrv@1/dlmfdrv@w50060e8010452150,1
6.c4t50060E800427FD10d1<
HITACHI-OPEN-V-SUN-5009cyl1331alt2hd15sec512>
/pseudo/dlmndrv@2/dlmfdrv@w50060e800427fd10,1
7.c4t50060E800427FD10d2<
/pseudo/dlmndrv@2/dlmfdrv@w50060e800427fd10,2
8.c4t50060E800427FD10d3<
/pseudo/dlmndrv@2/dlmfdrv@w50060e800427fd10,3
9.c4t50060E800427FD10d4<
/pseudo/dlmndrv@2/dlmfdrv@w50060e800427fd10,4
Specifydisk(enteritsnumber):
^D
#
启动HDML双击软件
#cd/opt
#ls
@LongLinkHDVMSUNWmlibTieredStorageManager
APPQcimeRMLIBSUNWrtvchitachi
DynamicLinkManagerSUNWitsTSM06-00-00_E01_SOL_CLI.tarsun
#cdDy*
binclassescommonconfigjnlpjrelibrcwebstart
#cdbin
DLMGLCLdlmcfgmgrdlmguiinst.shdlmmgrdlmwebgui_setup.sh
DLMLocal.jardlmgetomtracedlmguiuninst.shdlmsetconfdlnkmgr
DLMgetrasdlmgetrasdlminstcompdlmsetdevnamehcmdslicense2
UtilAudLogdlmglcldlmlisthdevdlmvxexclude
#./dlmsetconf
KAPL10242-IToconfigureHDLM,devicefilesofsd/ssddevicesmanagedbyHDLMareremovedafterreboot.
Doyouwanttocontinue?
[y/n]:
y
KAPL10204-Idlmsetconfcompletedsuccessfully.
#./dlmcfgadm-a
./dlmcfgadm:
notfound
#./dlmcfgmgr-a
KAPL10373-IThisoperationwillchangetheconfigurationofHDLMdevices,anddeletedevicefilesofsd/ssddevicesmanagedbyHDLM.
KAPL10378-ITheLU(LDEV=AMS.83011013.0007)wassuccessfullyadded.
KAPL10370-Idlmcfgmgrcompletedsuccessfully.
第5章阵列常用软件配置
5.1VolumeMigration
5.1.1功能介绍
HDS的VolumeMigration功能等价于EMC的LUNMigration,可以实现同一台阵列内LUN的在线迁移,迁移过程中不需要中断主机对LUN的读写。
AMS2000系列免费提供该功能。
5.1.2组成部分
●MigrationPair
包含P-Volume和S-Volume。
P-Volume含义为PrimaryVolume,Migration的源LUN。
S-Volume含义为SecondaryVolume,Migration的目标LUN。
P-Volume和S-Volume的RAID类型可以不同,但要求容量相同。
为了保证S-Volume容量和P-Volume容量相同,在创建S-Volume时,可以参照P-Volume的Block数量。
●ReservedLU
需要将作为S-Volume的LUN设置为ReservedLUN。
●DMLU
需要创建一个10G的DMLUN。
DMLU最小为10G,建议大小10G。
为了保证高可用性,有条件的话可以在两个RAIDGroup中分别创建一个DMLU。
一台阵列最多可以配置两个DMLU。
●StorageNavigatorModular
本文中使用SNM2来配置VolumeMigration
●CCI(可选)
可以使用CCI配置VolumeMigration,本文未作描述。
5.1.3操作步骤
1.设置DMLU。
设置一个即可,最小容量10G,推荐容量10G。
每个阵列最多可以设置两个DMLU,以实现高可用。
如果设置两个DMLU,建议将两个DMLU创建在不同的RAIDGroup中。
查看设置结果
2.